New five-story, 200,000 SF core and shell, Class A office building with an 86,000 SF level of underground parking for 245 cars.
The structure is a steel brace frame atop a five-ft.-thick concrete mat slab. Scope included demo of existing parking lot and re-routing of existing utilities away from project excavation.
The project was Design-Build for the MEP systems and shoring. It was critical to get the shoring subconsultant on board early to coordinate with existing site utilities.The building also was constructed on an occupied campus with very tight logistics that included providing uninterrupted access to the VTA light rail station on the site. Level 10’s team maintained schedule despite having to eliminate unexpected groundwater during construction of the 20-ft.-deep underground parking.
LEED Gold certified.
Related Services
Preconstruction
Design Assist/Design-Build MEP+
Self-Perform Work
Sustainability
Media Gallery (4)
LEED® Gold
EMAIL UPDATES
Signup with your email address below and we will keep you up to date on the latest Level 10 Construction news and project achievements (new , recently completed, awards and recognition)
Thank you for signing up
Project Executive
Email Doug Collins
Thank you for your message.
We appreciate you taking the time to reach out.
If the nature of your inquiry requires follow up we will reach out to you as soon as possible.